This XPSCM safety module is for monitoring of single-beam photo-electric sensors and has a built-in "muting" function. It meets the requirements of PL c/Category 2 conforming to EN/ISO 13849-1.and SILCL1 conforming to EN/IEC 61508 and EN/IEC 62061. Used in conjunction with XU2S single-beam photo-electric sensors (periodically tested), it establishes a category 2 light curtain conforming to IEC/EN 61496 parts 1 and 2.
- Range of Product: Telemecanique Safety Light Curtains XUSL
- Product or Component Type: Safety Module
- Safety Module Name: XPSCM
- Safety Module Application: For monitoring of single-beam photo-electric sensor
- Function of Module: Built-in muting
- Safety Level:
Can reach Category 2 with the appropriate control system and correctly wired conforming to EN/ISO 13849-1
Can reach SILCL 1 with the appropriate control system and correctly wired conforming to EN/IEC 62061
Can reach PL = c with the appropriate control system and correctly wired conforming to EN/ISO 13849-1 - Safety Reliability Data:
MTTFd = 16.6 years conforming to EN/ISO 13849-1
DC = 95.5% conforming to EN/ISO 13849-1
PFH = 3.12E-7 1/h conforming to EN/IEC 61508
PFHd = 3.12E-7 1/h conforming to EN/IEC 62061 - Number of Inputs:
2 (terminals MA, MB) for muting function
4 (terminals Z1, Z2, Z3, Z4) for sensor - Input Voltage:
24 V DC for sensor
24 V DC (terminals U+, U-) for muting function - Input Compatibility:
XC limit switch for muting function
XU2M18PP340... for muting function
XU2S18PP340... (infrared) for sensor
XU9M18PP340... for muting function - Connections - Terminals:
Captive screw clamp terminals: - 1 x 0.14...1 x 2.5 mm² solid or flexible without cable end
- 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel
- 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel
- 2 x 0.14...2 x 0.75 mm² solid or flexible without cable end
- 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel
- 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
- Output Type: Relay 2 NO (13-14, 23-24), volt-free
- Number of Additional Circuits: 0
- Rated Supply Voltage: 24 V DC -20...20%
Complementary
Sensor Power Supply:
- U+, U-: 24 V DC
- Maximum Supply Current for Sensors: 200 mA
Input Current:
- 200 mA for muting function
Synchronization Time Between Inputs:
- 3 s (+/- 20%) for the activation of the MA/MB muting signal
Muting Maximum Duration:
Maximum Line Resistance:
- 10 Ohm for sensor power supply
Breaking Capacity:
- 180 VA holding AC-15 C300 relay output
- 1800 VA inrush AC-15 C300 relay output
- 20 mA at 24 V for solid-state output
- 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
Associated Fuse Rating:
- 4 A gG for relay output conforming to DIN VDE 0660 part 200
- 4 A gG for relay output conforming to EN/IEC 60947-5-1
- 6 A fast blow for relay output conforming to DIN VDE 0660 part 200
- 6 A fast blow for relay output conforming to EN/IEC 60947-5-1
Minimum Output Current:
Minimum Output Voltage:
Maximum Response Time on Input Open:
Local Signaling:
- 1 LED, function electronic internal fuse status
- 1 LED, function restarting
- 1 LED, function safety outputs closed
- 1 LED, function safety outputs open
- 1 incandescent lamp, function muting power consumption: 4…6.5 W
Output Thermal Current:
- 5.6 A per relay
- 11 A maximum
Power Consumption in W:
Protection Type:
Rated Insulation Voltage [Ui]:
- 300 V (pollution degree 2) conforming to DIN VDE 0110 parts 1 and 2
- 300 V (pollution degree 2) conforming to EN/IEC 60947-5-1
Rated Impulse Withstand Voltage [Uimp]:
- 4 kV overvoltage category III conforming to DIN VDE 0110 parts 1 and 2
- 4 kV overvoltage category III conforming to EN/IEC 60947-5-1
Environment:
- Ambient Air Temperature for Operation: -10…55 °C
- Ambient Air Temperature for Storage: -25…85 °C
- IP Degree of Protection:
- IP20 (terminals) conforming to IEC 60529
- IP40 (enclosure) conforming to IEC 60529